Flexible
Single &
Multiconductor
Stranded
Bare or
Tinned Copper
PVC
Jacket
PVC & PVC
Insulated
Cables
Tinned Copper
Braided
Shield
600
Volts,
105°
C
PVC
Insulated
Conductor
DESCRIPTION:
Conductors
are
bare
or
tin-plated
copper
strands
insulated
with
10
mil
wall
of
color
coded
PVC.
Braided
shields,
jackets
or
both
can
be
applied
over
the
cabled
conductors
prior
to
jacketing
with
PVC.
For
special
applications,
spiral
shields
can
be
substituted
for
braided
shields.
USE:
For
applications
requiring
good
flexibility
with
a
600
volt
rating.
Please
contact
our
design
team
for
your
specifiic
application.
JACKET
SINGLE
CONDUCTOR
DATA
SHIELD
Nominal
Nominal
Diameter
Diameter
Over
Over
Cabled
Number
of
Equivalent
Strand
Nominal
Wall
Nominal
AWG
of
Nominal
Wall
Nominal
Shield
Conductor
Conductors
AWG
Construction
Thickness
Diameter
Shield
Thickness
OD
1
.010
.060
.010
.040
40
.026
.026
7/44
36
1
.010
.061
.010
.041
40
.027
.027
10/44
34
1
.010
.062
.010
.042
40
.028
.028
7/42
34
1
.010
.063
.010
.043
40
.029
.029
7/40
32
1
.010
.064
.010
.044
40
.030
.030
19/44
32
1
.010
.066
.010
.046
40
.032
.032
11/40
30
1
.010
.066
.010
.046
40
.032
.032
7/38
30
1
.010
.069
.010
.049
40
.035
.035
19/40
28
1
.010
.069
.010
.049
40
.035
.035
7/36
28
1
.010
.072
.010
.052
40
.038
.038
26/40
26
1
.010
.073
.010
.053
40
.039
.039
19/38
26
1
.010
.077
.010
.057
40
.043
.043
42/40
24
1
.010
.078
.010
.058
40
.044
.044
19/36
24
2
.010
.085
.010
.065
40
.051
.026
7/44
36
2
.010
.087
.010
.067
40
.053
.027
10/44
34
2
.010
.089
.010
.069
40
.055
.028
7/42
34
2
.010
.091
.010
.071
40
.057
.029
7/40
32
2
.010
.093
.010
.073
40
.059
.030
19/44
32
2
.010
.097
.010
.077
40
.063
.032
11/40
30
2
.010
.097
.010
.077
40
.063
.032
7/38
30
2
.010
.103
.010
.083
40
.069
.035
19/40
28
2
.010
.103
.010
.083
40
.069
.035
7/36
28
2
.010
.108
.010
.088
40
.074
.038
26/40
26
2
.010
.110
.010
.090
40
.076
.039
19/38
26
2
.010
.118
.010
.098
40
.084
.043
42/40
24
2
.010
.120
.010
.100
40
.086
.044
19/36
24
3
.010
.090
.010
.070
40
.056
.026
7/44
36
3
.010
.092
.010
.072
40
.058
.027
10/44
34
3
.010
.094
.010
.074
40
.060
.028
7/42
34
3
.010
.096
.010
.076
40
.062
.029
7/40
32
3
.010
.099
.010
.079
40
.065
.030
19/44
32
3
.010
.103
.010
.083
40
.069
.032
11/40
30
3
.010
.103
.010
.083
40
.069
.032
7/38
30
3
.010
.109
.010
.089
40
.075
.035
19/40
28
3
.010
.109
.010
.089
40
.075
.035
7/36
28
3
.010
.116
.010
.096
40
.082
.038
26/40
26
3
.010
.118
.010
.098
40
.084
.039
19/38
26
3
.010
.136
.015
.106
40
.092
.043
42/40
24
3
.010
.139
.015
.109
40
.095
.044
19/36
24
All
measurements
are
in
inches
unless
otherwise stated.
w w w. n e w e n g l a n d w i r e . c o m
Te l : 6 0 3 . 8 3 8 . 6 6 2 4
©
2005
New
England Wire Technologies
69