Ij

Next Page
Previous Page
Table of Contents
PDF Printable
Silver-plated
Ultra Flexible Single & Multiconductor
Silver-Plated
Copper
PFA Jacket
Copper Shield
PFA Insulated Cables
125 Volts, 260° C
Microminiature PFA
Insulated Conductor
DESCRIPTION: Conductors are ultra flexible silver-plated copper strands insulated with 3.5 mil walls of PFA. Extra
flexible silver-plated copper braided shields can be applied over the cabled conductors prior to jacketing with PFA.
USE: Used primarly in medical instruments such as transducers, flow probes, peripheral telemetry equipment
and other specialized applications where strong, ultra flexible, microminiature multiconductor cables are required.
Please contact our design team for constructions applicable to your specific requirements.
SHIELD
JACKET
SINGLE CONDUCTOR DATA
Nominal
Diameter
Nominal
Over Cabled
Number of
Equivalent
Strand
Nominal Wall
Nominal
AWG of
Diameter Over
Nominal Wall
Nominal
Conductor
Conductors
AWG
Construction
Thickness
Diameter
Shield
Thickness
OD
Shield
1
40
10/50
.0035
.011
.020
.011
44
.006
.032
1
38
17/50
.0035
.012
.021
.012
44
.006
.033
1
36
26/50
.0035
.013
.022
.013
44
.006
.034
1
34
41/50
.0035
.014
.023
.014
44
.006
.035
1
33
52/50
.0035
.015
.024
.015
44
.006
.036
1
32
65/50
.0035
.016
.025
.016
44
.006
.037
1
31
75/50
.0035
.017
.026
.017
44
.006
.038
1
30
41/46
.0035
.019
.028
.019
44
.006
.040
1
28
65/46
.0035
.022
.031
.022
44
.006
.043
2
40
10/50
.0035
.011
.031
.022
44
.006
.043
2
38
17/50
.0035
.012
.033
.024
44
.006
.045
2
36
26/50
.0035
.013
.034
.025
44
.006
.046
2
34
41/50
.0035
.014
.036
.027
44
.006
.048
2
33
52/50
.0035
.015
.038
.029
44
.006
.050
2
32
65/50
.0035
.016
.040
.031
44
.006
.052
2
31
75/50
.0035
.017
.042
.033
44
.006
.054
2
30
41/46
.0035
.019
.046
.037
44
.006
.058
2
28
65/46
.0035
.022
.053
.044
44
.006
.065
3
40
10/50
.0035
.011
.033
.024
44
.006
.045
3
38
17/50
.0035
.012
.035
.026
44
.006
.047
3
36
26/50
.0035
.013
.037
.028
44
.006
.049
3
34
41/50
.0035
.014
.039
.030
44
.006
.051
3
33
52/50
.0035
.015
.041
.032
44
.006
.053
3
32
65/50
.0035
.016
.043
.034
44
.006
.055
3
31
75/50
.0035
.017
.046
.037
44
.006
.058
3
30
41/46
.0035
.019
.050
.041
44
.006
.062
3
28
65/46
.0035
.022
.056
.047
44
.006
.068
4
40
10/50
.0035
.011
.036
027
44
.006
.048
4
38
17/50
.0035
.012
.038
.029
44
.006
.050
4
36
26/50
.0035
.013
.040
.031
44
.006
.052
4
34
41/50
.0035
.014
.043
.034
44
.006
.055
4
33
52/50
.0035
.015
.045
.036
44
.006
.057
All measurements are in inches unless otherwise stated.
w w w. n e w e n g l a n d w i r e . c o m
Te l : 6 0 3 . 8 3 8 . 6 6 2 4
© 2005 New England Wire Technologies
45