NEWind® Specialty Winding Wire
TECHNICAL
The most common winding wire is magnet wire in either its single-end or
INFORMATION
stranded Litz form. Magnet wire coating, however is generally not sufficient
for insulating between winding turns, separate windings and between the
winding and ground as the magnet wire coating can easily be damaged.
It is for this reason that additional interleaved insulation is needed.
NEWind®Specialty Winding Wire eliminates the need for this additional insu-
lation by insulating conductors with thin layers of insulation extruded in sin-
gle (Basic), two (Supplemental) or three (Reinforced) layers. Basic NEWind®
is recommended when a rating of 600 Vpk and the smallest
possible diameter are required. Supplemental and Reinforced NEWind® are
used where a more rugged product is required to withstand mechnical
handling and maintain an electrical rating up to 1000 Vpk. These products
are also approved under our NE-F1 Electrical Insulation System.
Multiple Insulation on Complex Bundles
Multiple Insulation on Single Strand
PRODUCT DETAILS
·
UL 60950/IEC 60950 Annex U Approved
·
UL 1446 Electrical Insulation System: NE-F1 - Class F (155°C)
·
Single-End, Stranded and Litz Conductors
·
Supplementary and Reinforced Insulations
MATERIAL
PFA
FEP
ETFE
PROPERTIES
Temperature
155°C
180°C
200°C*
Rating*
Layer Thickness
.0015
.002
.002
Basic
(Minimum)
Total Thickness
.003
.004
.004
Supplementary
(Minimum)
Total Thickness
.0045
.006
.006
Reinforced
(Minimum)
*UL60950 & VDE 60950 have a maximum temperature rating of 180°C Class H.
w w w. n e w e n g l a n d w i r e . c o m
Te l : 6 0 3 . 8 3 8 . 6 6 2 4
© 2005 New England Wire Technologies
183