Tinned Copper
Extra Flexible PVC Insulated Power Cables
300 Volts,
105º
C
PVC
Insulation
UL
10198,
CSA
Approved,
VW-1
Rated
USE:
UL10198
- Ground
strap
lead
wire
for
internal
wiring
of
electronic
equipment
where
acceptability
of
the
combination
is to be
determined
by UL,
Inc.
Stocked
New
England
Equivalent
Number
of
Strand
Cable
Minimal
Wall
Nominal
OD
2
Item*
Part
Number
AWG
Size
Construction
Strands
AWG
Size
Thickness
OD
65/36
N20-36T-467-R01-X1UC
65
18
36
.047
.015
.080
7x9/36
N20-36T-417-R01-X1UC
63
18
36
.049
.015
.083
7x15/36
N20-36T-510-R01-X1UC
105
16
36
.063
.015
.098
7x24/36
N30-36T-569-R01-X1UC
168
14
36
.080
.020
.126
7x37/36
N30-36T-622-R01-X1UC
259
12
36
.099
.020
.146
B
7x59/36
N30-36T-673-X1UC
413
10
36
.126
.020
.173
B,R
7x95/36
N30-36T-737-X1UC
665
8
36
.159
.030
.235
B,R
7x119/36
N30-36T-739-X1UC
833
7
36
.178
.030
.249
7x150/36
N30-36T-775-X1UC
1050
6
36
.200
.030
.272
B
7x7x34/36
N30-36T-776-X1UC
1666
4
36
.271
.030
.349
B
7x7x54/36
N30-36T-815-X1UC
2646
2
36
.342
.030
.422
7x7x68/36
N30-36T-814-X1UC
3332
1
36
.383
.040
.488
7x7x86/36
N30-36T-857-X1UC
4214
1/0
36
.431
.040
.538
B
7x7x108/36
N40-36T-870-X1UC
5292
2/0
36
.483
.050
.614
B
19x7x51/36
N40-36T-905-X1UC
6783
3/0
36
.547
.060
.679
19x7x64/36
N40-36T-960-X1UC
8512
4/0
36
.613
.080
.789
Extra Flexible PVC Insulated Power Cables
*STOCKED
ITEMS: B =
Black
jacket
w/white
print
R =
Red
jacket
w/white
print
600 Volts,
105º
C
W =
White
jacket
w/black
print
UL
10070,
CSA
Approved,
VW-1
Rated
USE:
Internal
wiring
of
computers
and
electronic
equipment.
Stocked
New
England
Equivalent
Number
of
Strand
Cable
Minimal
Wall
Nominal
OD
2
Item*
Part
Number
AWG
Size
Construction
Strands
AWG
Size
OD
Thickness
.030
.047
.113
65
N30-36T-459-R01-X1UC
65/36
18
36
.030
.049
.116
63
N30-36T-417-R01-X1UC
7x9/36
18
36
.030
.063
.131
105
N30-36T-516-R01-X1UC
7x15/36
16
36
.030
.082
.148
168
N30-36T-566-R01-X1UC
7x24/36
14
36
B,W
.030
.099
.168
259
N30-36T-617-R01-X1UC
7x37/36
12
36
B,R
.030
.126
.195
413
B,W,R,
N30-36T-669-X1UC
7x59/36
10
36
.045
.159
.263
665
N30-36T-731-X1UC
7x95/36
8
36
B
.060
.178
.315
833
N40-36T-713-X1UC
7x119/36
7
36
.060
.200
.338
1050
N40-36T-767-X1UC
7x150/36
6
36
B
.060
.271
.415
1666
N40-36T-764-R01-X1UC
7x7x34/36
4
36
B
.060
.342
.488
2646
N40-36T-822-X1UC
7x7x54/36
2
36
B
.080
.383
.576
3332
N40-36T-823-X1UC
7x7x68/36
1
36
.080
.431
.626
4214
N40-36T-869-X1UC
7x7x86/36
1/0
36
.080
.483
.680
5292
N40-36T-871-X1UC
7x7x108/36
2/0
36
.080
.547
.723
6783
N40-36T-906-X1UC
19x7x51/36
3/0
36
.080
.613
.789
8512
N40-36T-961-X1UC
19x7x64/36
4/0
36
1.
PVC
colors
designated
by
numbered
suffix
in
place
of
the
first
"X"
in
the
above
part
numbers:
1 -
white;
2 -
black;
3 -
red;
4 -
green;
5 -
yellow;
6 - blue;
7 -
brown;
8 -
orange;
9 -
gray;
10 -
violet
2.
The
uninsulated
cable
diameter is determined
when
the
cable
is
under
tension
during
the
extrusion
process.
Please
request
a sample of
our
cable
for
evaluation
prior
to
making
decisions
regarding
connectors
to be
used.
3. Cable printed in
white
or
black.
All
measurements
are
in
inches
unless
otherwise stated.
106