Ij

Next Page
Previous Page
Table of Contents
PDF Printable
Tinned Copper
Extra Flexible PVC Insulated Power Cables
300 Volts, 105º C
PVC Insulation
UL 10198, CSA Approved, VW-1 Rated
USE: UL10198 - Ground strap lead wire for internal wiring of electronic equipment where acceptability of the
combination is to be determined by UL, Inc.
Stocked
New England
Equivalent
Number of
Strand
Cable
Minimal Wall
Nominal
OD 2
Item*
Part Number
AWG Size
Construction
Strands
AWG Size
Thickness
OD
65/36
N20-36T-467-R01-X1UC
65
18
36
.047
.015
.080
7x9/36
N20-36T-417-R01-X1UC
63
18
36
.049
.015
.083
7x15/36
N20-36T-510-R01-X1UC
105
16
36
.063
.015
.098
7x24/36
N30-36T-569-R01-X1UC
168
14
36
.080
.020
.126
7x37/36
N30-36T-622-R01-X1UC
259
12
36
.099
.020
.146
B
7x59/36
N30-36T-673-X1UC
413
10
36
.126
.020
.173
B,R
7x95/36
N30-36T-737-X1UC
665
8
36
.159
.030
.235
B,R
7x119/36
N30-36T-739-X1UC
833
7
36
.178
.030
.249
7x150/36
N30-36T-775-X1UC
1050
6
36
.200
.030
.272
B
7x7x34/36
N30-36T-776-X1UC
1666
4
36
.271
.030
.349
B
7x7x54/36
N30-36T-815-X1UC
2646
2
36
.342
.030
.422
7x7x68/36
N30-36T-814-X1UC
3332
1
36
.383
.040
.488
7x7x86/36
N30-36T-857-X1UC
4214
1/0
36
.431
.040
.538
B
7x7x108/36
N40-36T-870-X1UC
5292
2/0
36
.483
.050
.614
B
19x7x51/36
N40-36T-905-X1UC
6783
3/0
36
.547
.060
.679
19x7x64/36
N40-36T-960-X1UC
8512
4/0
36
.613
.080
.789
Extra Flexible PVC Insulated Power Cables
*STOCKED ITEMS: B = Black jacket w/white print
R = Red jacket w/white print
600 Volts, 105º C
W = White jacket w/black print
UL 10070, CSA Approved, VW-1 Rated
USE: Internal wiring of computers and electronic equipment.
Stocked
New England
Equivalent
Number of
Strand
Cable
Minimal Wall
Nominal
OD 2
Item*
Part Number
AWG Size
Construction
Strands
AWG Size
OD
Thickness
.030
.047
.113
65
N30-36T-459-R01-X1UC
65/36
18
36
.030
.049
.116
63
N30-36T-417-R01-X1UC
7x9/36
18
36
.030
.063
.131
105
N30-36T-516-R01-X1UC
7x15/36
16
36
.030
.082
.148
168
N30-36T-566-R01-X1UC
7x24/36
14
36
B,W
.030
.099
.168
259
N30-36T-617-R01-X1UC
7x37/36
12
36
B,R
.030
.126
.195
413
B,W,R, N30-36T-669-X1UC
7x59/36
10
36
.045
.159
.263
665
N30-36T-731-X1UC
7x95/36
8
36
B
.060
.178
.315
833
N40-36T-713-X1UC
7x119/36
7
36
.060
.200
.338
1050
N40-36T-767-X1UC
7x150/36
6
36
B
.060
.271
.415
1666
N40-36T-764-R01-X1UC
7x7x34/36
4
36
B
.060
.342
.488
2646
N40-36T-822-X1UC
7x7x54/36
2
36
B
.080
.383
.576
3332
N40-36T-823-X1UC
7x7x68/36
1
36
.080
.431
.626
4214
N40-36T-869-X1UC
7x7x86/36
1/0
36
.080
.483
.680
5292
N40-36T-871-X1UC
7x7x108/36
2/0
36
.080
.547
.723
6783
N40-36T-906-X1UC
19x7x51/36
3/0
36
.080
.613
.789
8512
N40-36T-961-X1UC
19x7x64/36
4/0
36
1. PVC colors designated by numbered suffix in place of the first "X" in the above part numbers: 1 - white; 2 - black; 3 - red; 4 - green; 5 - yellow; 6 - blue;
7 - brown; 8 - orange; 9 - gray; 10 - violet
2. The uninsulated cable diameter is determined when the cable is under tension during the extrusion process. Please request a sample of our cable for
evaluation prior to making decisions regarding connectors to be used.
3. Cable printed in white or black.
All measurements are in inches unless otherwise stated.
106