NEWind® Specialty Winding Wire
The most common winding wire is magnet wire in either its single-end or
TECHNICAL
stranded Litz form. Magnet wire coating, however is generally not sufficient
INFORMATION
for insulating between winding turns, separate windings and between the
winding and ground as the magnet wire coating can easily be damaged.
It is for this reason that additional interleaved insulation is needed.
NEWind® Specialty Winding Wire eliminates the need for this additional
insulation by insulating conductors with thin layers of insulation extruded
in single (Basic), double (Supplemental) or triple (Reinforced) layers. Basic
NEWind® is recommended when a rating of 600 Vpk and the smallest
possible diameter are required. Supplemental and Reinforced NEWind®
are used where a more rugged product is required to withstand mechanical
handling and maintain an electrical rating up to 1000 Vpk. These products
are also approved under our NE-F1 Electrical Insulation System.
Multiple Insulation on Single Strand
Multiple Insulation on Complex Bundles
PRODUCT DETAILS
·
UL 60950/IEC 60950 Annex U Approved
·
UL 1446 Electrical Insulation System: NE-F1 - Class F (155°C)
·
Single-End, Stranded and Litz Conductors
·
Supplementary and Reinforced Insulations
MATERIAL
ETFE
PFA
FEP
PROPERTIES
Temperature
155°C
180°C
200°C*
Rating*
Layer Thickness
.0015
.002
.002
Basic
(Minimum)
Total Thickness
.003
.004
.004
Supplementary
(Minimum)
Total Thickness
.0045
.006
.006
Reinforced
(Minimum)
*UL60950 & VDE 60950 have a maximum temperature rating of 180°C Class H.